| Protection required | RCCB (residual-current protection only) or RCBO (residual-current and overcurrent protection) | An RCCB does not provide overload or short-circuit protection. An RCBO combines those functions in one device. | Choose an RCCB when suitable overcurrent protection is provided separately. Consider an RCBO for individual circuit protection. |
| Residual-current waveform | Type AC, Type A, Type F, or Type B | The type indicates which residual-current waveforms the device is designed to detect. | Match the device type to the connected equipment and its instructions. Type A detects sinusoidal AC and pulsating DC residual currents; Type F and Type B cover additional waveform conditions. |
| Connected equipment | Resistive loads, electronic equipment, variable-speed drives, or equipment that may produce smooth DC residual current | Electronic power conversion can create residual-current waveforms that a basic Type AC device may not detect as intended. | Check appliance or equipment documentation. Type F is intended for certain single-phase inverter or variable-speed applications; Type B is used where smooth DC residual currents may occur. |
| Rated residual operating current | Common ratings include 30 mA, 100 mA, and 300 mA | The rating describes the residual current at which the device is designed to operate under specified conditions. | A 30 mA device is commonly used for additional protection against electric shock where required. Higher ratings may be used for other protection purposes; follow local regulations and the installation design. |
| Rated current and overcurrent protection | Device current rating, circuit load, and upstream protective device | For an RCCB, the rated current is not an overload trip setting. The circuit still needs appropriate overload and short-circuit protection. | Coordinate the RCCB rating with the circuit design and its upstream overcurrent protection. For an RCBO, check its rated current and trip characteristics against the circuit requirements. |
| Poles and supply system | Number of poles and single-phase or three-phase supply | The device must suit the supply arrangement and the conductors that need to be switched and monitored. | Confirm the required pole configuration and wiring arrangement against the panel design and local electrical rules. |
| Unwanted tripping and coordination | Leakage current from connected equipment, circuit grouping, and selective time delay | Cumulative normal leakage current can contribute to unwanted operation. Selective devices may help coordinate protection in suitable installations. | Review expected leakage current and divide circuits appropriately. Use time-delayed or selective devices only where permitted and properly coordinated with downstream protection. |
| Standards and installation conditions | Applicable electrical code, product marking, ambient conditions, and manufacturer instructions | Rules and device requirements vary by country, application, and installation. | Verify compliance with local regulations and have selection, installation, and testing carried out by a qualified electrical professional. |