| Straight Union | Two push-in ports in line; commonly joins tubing of the same outside diameter. | Connecting two tube sections or extending a pneumatic line. | Cut both tube ends square, remove burrs, and push each tube fully into its port. | Check both connections for leaks after pressurizing. Support long tube runs to reduce strain on the fitting. |
| Male Straight Connector | Push-in tube port with a male threaded end. | Connecting tubing to a threaded valve, manifold, cylinder, or other port. | Confirm thread type and size before assembly. Use an appropriate thread seal where required; keep sealant out of the air passage. | Do not overtighten, as excessive torque can damage threads or the component port. Inspect for leakage at both interfaces. |
| Female Connector | Push-in tube port with a female threaded connection. | Joining tubing to a component with a matching male thread. | Verify the thread standard and sealing method. Align the fitting before tightening to avoid cross-threading. | Check the threaded joint and tube connection separately during leak testing. Replace damaged seals or fittings. |
| Elbow Connector | Usually a 90-degree tube-to-tube or tube-to-threaded-port connection. | Routing tubing around obstacles or changing direction in a compact installation. | Choose an elbow that allows the tubing to meet its minimum bend-radius requirements without kinking. | Avoid using the fitting to force a tight bend. Check for tube abrasion, side loading, and leakage during routine inspections. |
| Tee Connector | Three ports arranged to create a branch from a main line. | Supplying air to two branches or adding a connection point to a circuit. | Confirm port sizes and plan the branch layout to avoid unnecessary restrictions or unsupported tubing. | Isolate and depressurize the circuit before changing connections. Inspect all three ports for leaks and tube movement. |
| Y Connector | Three ports with a branching shape designed to divide or combine tube runs. | Creating a split with a more gradual tube path than a sharp branch arrangement. | Check the flow direction and circuit design; a Y fitting does not regulate or balance flow between branches. | Secure both branches to prevent vibration and pullout. Confirm that each branch receives the intended airflow. |
| Bulkhead Union | Tube-to-tube connection mounted through a panel or enclosure wall. | Passing a pneumatic line through a machine guard, cabinet, or partition. | Use the specified panel-hole size and mounting thickness. Tighten the locknut without distorting the panel or fitting. | Inspect the mounting and tube connections for loosening, vibration, or leakage, especially on moving equipment. |
| Reducer | Push-in ports sized for different tubing outside diameters. | Connecting tube sizes when a circuit transitions between line sections. | Match each tube to the port marked for its outside diameter. Do not force oversized or undersized tubing into a port. | Check that the smaller line does not create an unacceptable flow restriction. Replace a fitting if its collet or seal is damaged. |
| Swivel Elbow | Angled tube port with a rotating or orientable body, depending on design. | Setting tube direction in confined spaces or reducing twisting during assembly. | Orient the fitting before final tightening where the design permits. Follow the specified torque and adjustment procedure. | Do not rotate a pressurized fitting unless it is specifically designed for adjustment under pressure. Check for loosening and leaks. |
| Flow-Control Fitting | Push-in tube connection with an adjustable flow-control element; some designs include a check valve. | Adjusting actuator speed by restricting airflow in a pneumatic circuit. | Install in the correct flow direction when the fitting is directional. Adjust gradually while observing machine behavior. | Never use flow control as a substitute for a rated pressure regulator or safety device. Isolate the machine before servicing. |
| End Plug | Push-in plug that closes an unused fitting port. | Sealing an unused port during commissioning or circuit changes. | Use a plug designed for the fitting series and port size. Insert it fully and confirm it is retained. | Verify the port is not needed before capping it. Depressurize the system before removing the plug. |