| Biomarker coverage | Amyloid-beta (Aβ42 and Aβ40) | Aβ42 and the Aβ42/Aβ40 ratio are used in cerebrospinal fluid (CSF) testing to assess amyloid pathology. Results and clinical interpretation depend on the assay, specimen handling, and validated decision limits. | Request assay-specific validation data, specimen requirements, measuring range, precision, and instructions for interpreting results. |
| Biomarker coverage | Phosphorylated tau (p-tau) | CSF and blood assays may measure different phosphorylated tau forms, such as p-tau181 or p-tau217. These forms and methods are not automatically interchangeable. | Confirm the exact analyte, sample type, method, intended-use population, and whether the evidence supports the proposed clinical use. |
| Biomarker coverage | Neurofilament light (NfL) and GFAP | NfL and glial fibrillary acidic protein (GFAP) can provide information about neuroaxonal injury or astroglial activity, but they are not specific to Alzheimer’s disease when used alone. | Check that product materials describe limitations clearly and do not present a nonspecific marker as a stand-alone Alzheimer’s diagnosis. |
| Product classification | Research-use-only (RUO) versus in-vitro diagnostic (IVD) | RUO products are intended for research and are not automatically authorized for clinical diagnosis. IVD products must meet applicable requirements in each market and for their stated intended purpose. | Verify product labeling, intended use, permitted claims, and market-specific regulatory status before clinical procurement. |
| Quality management | ISO 13485 | ISO 13485 specifies quality-management-system requirements for medical-device organizations. Certification can support supplier assessment but does not, by itself, establish that an individual assay is authorized or clinically valid. | Review the current certificate, its scope, issuing body, covered manufacturing sites, and any relevant audit or corrective-action records. |
| Risk management | ISO 14971 | ISO 14971 describes a risk-management process for medical devices, including identification, evaluation, control, and monitoring of risks throughout the product lifecycle. | Ask for evidence that risks related to specimen type, analytical performance, software, and result interpretation have been assessed and controlled. |
| Clinical laboratory use | ISO 15189 | ISO 15189 sets quality and competence requirements for medical laboratories. It applies to laboratories, not as a substitute for a product’s regulatory authorization. | For testing services, check the laboratory’s accreditation scope and whether the specific test and method are included. |
| European Union | In Vitro Diagnostic Regulation (EU) 2017/746 (IVDR) | IVDR governs IVD devices placed on the EU market. Classification, conformity assessment, performance evaluation, technical documentation, and other obligations depend on the device and its intended purpose. | Request the applicable conformity documentation and verify the product’s status and intended use for the EU market; do not rely on a general quality certificate alone. |
| United States | FDA requirements | U.S. requirements depend on the product, claims, and regulatory pathway. FDA authorization or clearance is product-specific; RUO labeling does not establish authorization for clinical use. | Check the FDA database and official product documentation for the exact product, manufacturer, intended use, and current regulatory status. |
| Analytical performance | Precision, accuracy, sensitivity, specificity, and measuring range | Performance characteristics should be established for the specific assay and specimen type. Results from different platforms may not be directly comparable without appropriate evidence. | Obtain validation or performance-evaluation reports, including study design, sample population, acceptance criteria, and limitations. |
| Calibration and traceability | Calibrators, controls, and reference materials | Calibration and quality-control materials help monitor assay performance. Availability of a reference material does not necessarily mean that all methods are fully harmonized. | Confirm calibrator assignment, lot documentation, control ranges, traceability claims, and procedures for monitoring lot-to-lot variation. |
| Specimen handling | Collection, transport, storage, and stability | CSF and blood biomarker results can be affected by collection tubes, processing time, storage temperature, freeze-thaw cycles, and other pre-analytical factors. | Request validated collection and stability instructions for each specimen type and confirm that shipping conditions can be maintained. |
| Manufacturing consistency | Lot release and change control | Consistent production and documented changes help preserve assay performance. A new reagent lot or manufacturing change may require verification or additional evaluation. | Ask for lot-specific certificates, release criteria, notification procedures for changes, and a documented process for handling nonconforming product. |
| Supplier qualification | Documentation and supply continuity | A robust supplier assessment considers quality systems, technical support, complaint handling, manufacturing controls, and continuity planning—not product claims alone. | Assess document control, response times, complaint and recall procedures, lead times, shelf life, cold-chain capability, and backup supply arrangements. |
| Clinical interpretation | Intended use and decision limits | Clinical interpretation should be tied to the assay’s validated population and use. A biomarker result alone does not necessarily establish a diagnosis or replace a complete clinical assessment. | Check that decision limits are supported by appropriate evidence and that reports explain intended use, limitations, and relevant clinical context. |