| Supplier Profile 01 | Glass-fiber microglass with protective support layers | 3–20 μm | β5 ≥ 1,000; β10 ≥ 1,000 | 20–30 bar | -30°C to 100°C | Nitrile, FKM | Mineral oils, selected phosphate-esters, water-glycol fluids | ISO 16889; ISO 2941 | Return-line, pressure-line, suction-line | Micron rating, length, end caps, seals, bypass valve | Material certificate, test report, dimensional inspection report | 3–6 weeks |
| Supplier Profile 02 | Stainless-steel wire mesh with pleated or cylindrical construction | 25–200 μm | β25 typically 2–20 | 15–25 bar | -40°C to 200°C | Nitrile, FKM, EPDM by application | Mineral oils, high-temperature fluids, selected fire-resistant fluids | ISO 2941; ISO 2942 | Reusable cleanable element, suction strainer, return element | Mesh size, frame material, connection dimensions | Mesh certificate, pressure-test record, dimensional report | 4–8 weeks |
| Supplier Profile 03 | Cellulose or resin-impregnated synthetic blend | 5–25 μm | β10 ≥ 200; β20 ≥ 1,000 | 10–20 bar | -25°C to 100°C | Nitrile, FKM | Standard mineral-based hydraulic oils | ISO 16889; ISO 2941 | Return-line and low-pressure filter elements | Media grade, pleat count, length, end-cap geometry | Batch traceability, flow test, visual inspection report | 2–5 weeks |
| Supplier Profile 04 | High-strength synthetic fiber media | 1–15 μm | β3 ≥ 1,000; β6 ≥ 1,000 | 25–35 bar | -30°C to 120°C | FKM, Nitrile | Mineral oils, biodegradable oils, selected water-glycol fluids | ISO 16889; ISO 2941; ISO 3968 | High-pressure, servo-valve, proportional-valve protection | Absolute rating, pressure class, bypass setting, sealing system | Bubble-point test, cleanliness report, pressure-drop curve | 5–8 weeks |
| Supplier Profile 05 | Stainless-steel fiber sintered media | 3–60 μm | β5 typically 100–1,000 | 30–50 bar | -40°C to 300°C | Metal-to-metal sealing or FKM | High-temperature oils, aggressive fluids, selected synthetic fluids | ISO 2941; ISO 2942; ISO 3968 | High-pressure and high-temperature filter elements | Porosity, sintering density, weld points, housing dimensions | Sintering record, material certificate, pressure and flow test | 6–10 weeks |
| Supplier Profile 06 | Multi-layer stainless-steel mesh with pleated support screen | 10–100 μm | β10 typically 20–200 | 20–40 bar | -40°C to 180°C | Nitrile, FKM, EPDM by fluid type | Mineral oils, fire-resistant fluids, water-based hydraulic fluids | ISO 2941; ISO 2942 | Cleanable pressure and return-line elements | Layer count, mesh grade, weld pattern, end-cap design | Mesh analysis, weld inspection, dimensional report | 4–7 weeks |
| Supplier Profile 07 | Glass-fiber media with epoxy or polymer support structure | 2–25 μm | β3 ≥ 1,000; β10 ≥ 1,000 | 18–30 bar | -30°C to 110°C | Nitrile, FKM, EPDM | Mineral oils, biodegradable oils, water-glycol fluids | ISO 16889; ISO 2941; ISO 3968 | Pressure, return, and offline kidney-loop filtration | Media efficiency, flow capacity, seals, bypass assembly | Multi-pass test data, pressure-drop curve, batch certificate | 3–7 weeks |
| Supplier Profile 08 | Polyester or polyamide synthetic nonwoven media | 5–40 μm | β10 ≥ 200; β20 ≥ 1,000 | 12–25 bar | -30°C to 120°C | Nitrile, FKM | Mineral oils and selected biodegradable hydraulic fluids | ISO 16889; ISO 2941 | Return-line, breather, and low-pressure applications | Media weight, pleat density, dimensions, seal material | Raw-material certificate, flow test, dimensional inspection | 2–6 weeks |
| Supplier Profile 09 | High-capacity glass-fiber and cellulose hybrid media | 10–30 μm | β10 ≥ 100; β20 ≥ 1,000 | 15–28 bar | -25°C to 100°C | Nitrile, FKM | Mineral oils and general-purpose hydraulic fluids | ISO 16889; ISO 3968 | High-dirt-holding-capacity return-line elements | Filtration rating, media blend, pleat count, length | Dirt-holding test, pressure-drop data, batch traceability | 3–6 weeks |
| Supplier Profile 10 | Stainless-steel mesh combined with synthetic fine-filtration layer | 3–50 μm | β5 ≥ 500; β10 ≥ 1,000 | 25–45 bar | -40°C to 150°C | FKM, Nitrile, EPDM by application | Mineral oils, water-glycol fluids, selected fire-resistant fluids | ISO 16889; ISO 2941; ISO 3968 | High-pressure and contamination-sensitive systems | Layer construction, absolute rating, bypass valve, connectors | Multi-pass test, pressure-resistance report, material certificate | 5–9 weeks |