| 1 | Intended use and regulatory status | Confirm whether the assay is for research use only or has authorization for a specified clinical use in the buyer’s target market. Check the exact specimen type, intended population, and use stated in the labeling. | Regulatory status and permitted use vary by product and jurisdiction. Research-use claims do not establish suitability for clinical diagnosis. | Current instructions for use, regulatory certificates or database entries where applicable, and a written statement of intended use and market availability. |
| 2 | Analytical performance | Review precision, analytical measuring range, limit of detection or quantification, reportable range, linearity, and interference testing for the intended sample matrix. | These characteristics indicate how consistently and reliably the assay measures pTau217 under defined laboratory conditions. | Validation reports, study protocols, acceptance criteria, and performance data for the exact assay configuration being offered. |
| 3 | Clinical evidence | Assess whether clinical studies used an appropriate population and reference method, and whether the evidence applies to the proposed specimen type and intended use. | Analytical performance alone does not establish clinical validity or utility. Study design and population affect how results can be interpreted. | Peer-reviewed publications, study summaries, protocol details, and information on study population, comparator, and limitations. |
| 4 | Cutoffs and result interpretation | Determine whether decision thresholds are established for the stated use, how indeterminate results are handled, and whether thresholds are validated for the local population and laboratory workflow. | Cutoffs can be method- and population-dependent. They should not be transferred between assays without supporting evidence. | Cutoff-development and validation data, interpretive guidance, and procedures for results near decision thresholds. |
| 5 | Specimen requirements and pre-analytics | Verify accepted specimen types, collection tubes, processing time, storage temperature, stability, freeze-thaw limits, and sample-volume requirements. | Pre-analytical handling can affect biomarker measurements and operational feasibility across collection sites. | Specimen collection and handling guide, stability data, and validated instructions for transport and storage. |
| 6 | Platform and workflow compatibility | Check required analyzer or reader, consumables, software, hands-on steps, throughput, run time, and whether the assay can be integrated into the laboratory’s existing processes. | Compatibility influences implementation effort, capacity, staffing, and total operating cost. | Instrument requirements, workflow diagrams, throughput specifications, and site-specific implementation assessment. |
| 7 | Quality systems and lot consistency | Review manufacturing quality controls, lot-release procedures, traceability, change control, and the availability of controls and calibrators. | Documented quality processes help laboratories manage reproducibility and investigate changes between reagent lots. | Quality-system documentation, lot-specific certificates, control instructions, and change-notification policy. |
| 8 | External quality assessment and verification support | Ask whether suitable external quality assessment or proficiency-testing options are available, and what support is provided for local method verification. | Independent quality assessment and documented local verification support ongoing confidence in laboratory results. | Available EQA or proficiency-testing information, verification protocols, training materials, and technical-support scope. |
| 9 | Supply continuity and global logistics | Evaluate manufacturing location, lead times, shelf life, cold-chain needs, regional distribution, customs documentation, and contingency arrangements. | Cross-border shipment and temperature-controlled handling can affect availability, costs, and product integrity. | Written supply plan, shipping and storage specifications, regional support details, and service-level commitments. |
| 10 | Total cost and commercial terms | Compare costs for instruments, reagents, controls, calibrators, service, training, shipping, and recurring consumables. Review minimum orders and contract terms. | Purchase price alone may not reflect the full cost of implementing and maintaining an assay program. | Itemized quotation, service and warranty terms, forecast-based pricing, and a clear schedule of recurring costs. |