| 1 | Identify the panel’s intended structural use. | Wood structural panels are used in applications such as roof sheathing, wall sheathing, and subflooring. A panel’s suitability depends on its grade, thickness, support spacing, and intended use. | Match the panel designation and installation instructions to the specific project and applicable building requirements. |
| 2 | Check whether the product claims compliance with PS 2-18. | PS 2-18 is a performance standard for wood structural panels. A reference to the standard is not, by itself, a complete design load table or a guarantee that a panel suits every application. | Verify the product’s identification and supporting compliance documentation; do not rely on advertising language alone. |
| 3 | Read the span rating on the panel marking. | A common span-rating format is “24/16”: the first number relates to maximum roof-support spacing and the second to maximum floor-support spacing, in inches on center, under the conditions specified for the panel. | Compare the marked rating with the actual framing spacing and the panel’s installation instructions. |
| 4 | Confirm the panel thickness and grade. | Thickness and grade affect structural performance. Nominal thickness descriptions and actual panel thickness can differ, so the product marking and technical documentation are important. | Check that the specified thickness and grade match the plans, framing layout, and applicable code requirements. |
| 5 | Distinguish Exposure 1 from Exterior classification. | Exposure 1 panels are intended for limited weather exposure during construction, while Exterior panels are intended for repeated wetting and drying. Neither classification means a panel is waterproof or suitable for permanent unprotected exposure. | Choose the exposure classification that matches construction conditions and the final assembly; provide required weather protection. |
| 6 | Compare structural claims with the exact manufacturer load table. | Allowable loads can vary with panel thickness, grade, span, support conditions, load direction, and design assumptions. A span rating alone does not provide every allowable load value. | Request the current load table for the exact panel and compare its stated conditions with the project design. |
| 7 | Check concentrated-load and deflection requirements. | Uniform-load capacity and deflection do not necessarily establish performance under concentrated loads, equipment loads, or other project-specific loading. | Have the design professional verify any unusual, concentrated, or serviceability-sensitive loads using applicable product data and design criteria. |
| 8 | Verify panel orientation and edge support requirements. | Panel instructions may specify orientation relative to supports, spacing between panels, and support or blocking at edges. These details affect how the installed assembly performs. | Follow the panel instructions and project drawings for orientation, panel gaps, fastening, and edge support. |
| 9 | Review fastening requirements. | Fastener type, size, spacing, and distance from panel edges are part of the installed assembly’s design. Requirements can differ by application and building code. | Use the fastening schedule in the approved plans or applicable instructions; do not assume one schedule fits every panel or use. |
| 10 | Inspect markings, condition, and documentation before purchase. | Clear panel identification helps connect the product to its grade, rating, and technical data. Damaged panels or panels exposed to unsuitable storage conditions may not meet project needs. | Check panel markings and condition, store panels as directed, and retain the relevant product documentation for verification. |
| Important: This comparison guide is for product evaluation, not structural design. Confirm required capacities and installation details with the current product documentation, project specifications, and applicable building code. Load values are product- and condition-specific and should not be inferred from this table. |