| 1. Fixed-parameter baseline | Nail material, diameter (mm), tip profile, exposed length (mm), penetration direction, and insertion speed (mm/s). | Cell format and dimensions, state of charge (SOC, %), starting temperature (°C), fixture, and test endpoint. | Peak and time-resolved voltage, temperature at defined locations, visible venting or fire, and time to each event. | Compare repeat samples or suppliers using one documented protocol. Keep the nail and setup identical across the comparison. |
| 2. Nail-speed sensitivity | Use the same nail material, diameter, tip profile, path, and penetration depth; vary insertion speed (mm/s) between test groups. | Keep cell type, SOC, temperature, fixture, and nail-to-cell alignment unchanged. | Actual speed and penetration depth, voltage response, temperature rise, and observed safety outcome. | Assess whether conclusions depend on insertion speed. Report measured speed, not just the equipment setting. |
| 3. Nail-diameter sensitivity | Vary nail diameter (mm) while keeping material, tip profile, insertion speed, direction, and penetration depth consistent. | Use cells from the same defined population and keep SOC, temperature, support, and test endpoint consistent. | Measured nail diameter, insertion force if instrumented, voltage and temperature traces, and safety outcome. | Check how a change in nail cross-section affects results. Do not compare diameter groups if other nail geometry also changes. |
| 4. Tip-profile or nail-material comparison | Change one factor at a time: tip profile or nail material. Document the profile and material; keep diameter and speed fixed where practicable. | Keep cell format, SOC, temperature, penetration path, fixture, and depth consistent. | Nail specification, insertion force if measured, penetration depth, voltage and temperature response, and observed outcome. | Determine whether results are specific to the chosen penetrator. A material or tip change should be treated as a protocol change. |
| 5. Orientation and penetration-path comparison | Specify the entry face, nail direction, target location, and penetration depth (mm). Keep nail geometry and speed fixed. | Use a positioning fixture; document cell orientation, dimensions, SOC, starting temperature, and any restraint. | Entry location and path, depth, alignment, voltage and temperature traces, and visible venting, leakage, or fire. | Evaluate sensitivity to test location and improve repeatability. Use separate, clearly defined groups for different orientations or paths. |
| Protocol note: Nail penetration conditions are not universal; the exact procedure and acceptance criteria depend on the applicable product standard, regulation, or buyer specification. These five methods are controlled experimental approaches, not a claim that one set of settings is a universal standard. UN 38.3 transport testing does not include a nail-penetration test. Perform testing in an appropriately equipped laboratory with a documented safety plan. |