| 1 | Power-line EMC filters | Attenuate conducted electromagnetic noise entering or leaving equipment through power connections. | Control cabinets, variable-speed drives, switching power supplies, and machine tools. | Match the filter to the supply voltage, current, frequency, installation environment, and expected noise paths. Follow the specified line, load, and protective-earth connections. | Conducted-emissions testing and immunity testing appropriate to the equipment and applicable product standards. |
| 2 | Shielded enclosures and cabinets | Reduce radiated emissions and help protect sensitive circuits from external electromagnetic fields. | Automation controllers, measurement systems, radio-frequency equipment, and sensitive instrumentation. | Evaluate seams, doors, ventilation openings, cable entries, and bonding. A shield can be compromised by gaps or poorly treated penetrations. | Radiated-emissions and radiated-immunity tests; inspect enclosure seams and cable-entry treatment. |
| 3 | Shielded cables with circumferential termination | Limit coupling between cables and nearby electromagnetic sources when the cable shield is correctly connected. | Encoder, sensor, motor, data, and control wiring in electrically noisy environments. | Select cable construction for the signal and environment. Use connectors or clamps that provide a low-impedance, broad-area shield connection where the design requires it. | Inspect shield continuity and termination quality; test the complete installation under representative operating conditions. |
| 4 | Equipotential bonding and protective earthing | Provide controlled paths for fault and interference currents and reduce voltage differences between conductive parts. | Machine frames, control cabinets, cable trays, and interconnected industrial equipment. | Follow electrical safety requirements and local regulations. Use short, reliable bonding connections and avoid relying on painted or corroded surfaces for electrical contact. | Protective-earth continuity and bonding inspections; verify the installation against applicable safety and EMC requirements. |
| 5 | Ferrite suppression components | Add frequency-dependent impedance that can reduce certain high-frequency common-mode currents. | Power, signal, and communication cables exhibiting localized high-frequency interference. | Choose a ferrite material and geometry suited to the frequency range and cable arrangement. Confirm that the component does not create unacceptable heating or affect signal performance. | Compare emissions or interference levels with and without the component across relevant operating conditions. |
| 6 | Surge protective devices | Limit transient overvoltages and divert surge currents, helping protect equipment from specified surge events. | Incoming power distribution, control panels, and signal or communication lines where surge exposure is considered. | Select devices for the system voltage, earthing arrangement, expected exposure, and required protection level. Coordinate protection stages and follow installation instructions. | Review device status and installation; use surge-immunity tests such as IEC 61000-4-5 where applicable. |
| 7 | Galvanic isolation | Interrupt direct conductive paths between circuits, which can help address ground loops and certain conducted disturbances. | Industrial communication links, measurement inputs, control interfaces, and selected power circuits. | Check isolation rating, working voltage, bandwidth, data rate, safety requirements, and the disturbance mechanisms the design is intended to address. | Verify insulation and functional performance; assess conducted immunity and communication integrity in the installed system. |
| 8 | Cable routing and physical separation | Reduce unintended coupling by managing the proximity and routing of noisy and sensitive circuits. | Control cabinets, machine wiring, motor-drive installations, and plant cable routes. | Separate power and low-level signal wiring where practical; minimize parallel runs and use crossings, routing, and segregation practices appropriate to the installation design. | Installation inspection and functional checks during switching, motor start-up, and other representative operating states. |
| 9 | Conductive gaskets and contact treatments | Maintain electrical continuity across enclosure joints and access panels, supporting enclosure shielding performance. | Cabinet doors, removable panels, access covers, and shielded equipment housings. | Consider compression, surface finish, corrosion, environmental exposure, and repeated opening. Ensure the gasket is compatible with the enclosure and its mechanical design. | Inspect contact continuity and enclosure condition; perform radiated testing when shielding performance is critical. |
| 10 | EMC testing and design validation | Identifies emissions and immunity weaknesses before deployment and helps confirm that corrective measures work. | New equipment, design changes, production qualification, and troubleshooting of field interference. | Define the intended markets, product category, operating modes, ports, and applicable standards before selecting tests. Requirements vary by equipment and jurisdiction. | Depending on the product, relevant references may include CISPR 11, IEC 61000-6-2, IEC 61000-6-4, and IEC 61000-4 series test methods. |