| Loft or pitched-roof insulation between framing | Approximately 20–50 | Declared thermal conductivity (λD), thickness, dimensions, and intended installation method | Prioritize the required thermal resistance and a suitable fit between framing. A higher density alone does not guarantee better insulation. |
| Internal partition or acoustic lining | Approximately 30–80 | Thickness, airflow resistivity or relevant acoustic test data, and the tested wall or ceiling assembly | Choose for the complete assembly, including board layers, cavity depth, and framing. Density by itself cannot predict sound reduction. |
| External wall insulation board | Approximately 80–150 | Tensile strength perpendicular to faces (TR), dimensional stability, water absorption, reaction to fire, and system approval | Match the board to the specified façade system and fixing method. Confirm that the declared strength and other properties meet the project requirements. |
| Flat-roof insulation board | Approximately 100–200 | Compressive stress at 10% deformation (CS(10)), point load (PL), thickness, water absorption, and roof-system compatibility | Use the structural or roofing specification to determine the required load performance. Do not select a roof board by density alone. |
| Industrial or equipment insulation | Product-specific; commonly about 40–180 | Service-temperature limits, thermal conductivity at the relevant mean temperature, dimensions, facing, and mechanical requirements | Check the operating temperature and the equipment design. Density ranges vary widely by product form and intended duty. |
| Any application where fire performance is required | Not selected by density alone | Declared reaction-to-fire classification, such as Euroclass under EN 13501-1, and any assembly-level fire requirements | Verify the classification on the product documentation and check whether the requirement applies to the insulation itself or the complete construction. |
| Product-document check before purchase | Compare the declared value with the project specification | Product standard, declared density or density tolerance, λD, thickness tolerance, mechanical properties, fire classification, and water-related performance | Use the current technical data sheet and Declaration of Performance where applicable. Compare products at the same thickness and intended use. |