| 630 | Choose a trip-unit rating and settings that suit the calculated design current; the frame rating alone does not define the protection setting. | Smaller main switchboards, building distribution, or large outgoing feeders. | Available trip-unit ratings, adjustment range, continuous-current limits, and terminal compatibility. |
| 800 | Confirm that the selected rated current and protection settings coordinate with the conductor ampacity and upstream protection. | Distribution boards serving commercial or light-industrial loads. | Permitted settings, protection functions, and required accessories for the intended installation. |
| 1,000 | Base selection on the maximum expected load and applicable ambient-temperature or enclosure derating. | Main or tie breakers in medium-sized facility switchboards. | Derating data, trip-unit curves, and the breaker’s tested ratings at the system voltage. |
| 1,250 | Check that the selected current rating supports the load while providing protection appropriate to the connected conductors and equipment. | Facility mains, larger distribution sections, or substantial feeder circuits. | Trip-unit options, sensor or rating-plug details where applicable, and coordination documentation. |
| 1,600 | Compare the calculated demand current with the breaker’s continuous-current capability under actual installation conditions. | Large commercial and industrial switchboards, including main and feeder positions. | Temperature-rise and derating information, connection arrangement, and service or draw-out configuration. |
| 2,000 | Ensure the trip settings can be configured for the load, cable protection, and selectivity requirements of the system. | Industrial mains, large feeders, or bus-section applications. | Long-time, short-time, instantaneous, and ground-fault functions, as required by the design. |
| 2,500 | Check load growth and operating scenarios, but do not use extra frame capacity as a substitute for correctly set protection. | High-capacity industrial distribution and large bus-tie duties. | Short-circuit ratings, selectivity data, and compatibility with the switchboard bus system. |
| 3,200 | Confirm continuous-current performance for the specified enclosure, ambient conditions, and mounting arrangement. | Large industrial mains, generator connections, or major distribution sections. | Application-specific ratings, connection and installation limits, and tested switchboard arrangements. |
| 4,000 | Validate the actual required current rating and allowable settings against load studies and protection coordination. | High-capacity plant mains, large generator systems, and major bus sections. | Breaking and withstand ratings at the project voltage, plus busbar and termination requirements. |
| 5,000 | Check whether the rating is available for the required breaker configuration and operating duty; availability can vary by product range. | Specialized high-current industrial distribution and large bus-coupler installations. | Certified configuration, thermal limits, fault-duty data, and engineering support for the complete assembly. |
| 6,300 | Treat this as a high-current application: verify the exact rated current, operating conditions, and system study results for the selected assembly. | Very large industrial mains, major generation connections, and high-capacity bus systems. | Rated-current and short-circuit test certificates, busbar interface, installation limits, and project-specific technical support. |