| Amperometric, membrane-covered | Continuous monitoring of free chlorine in treated water and distribution systems. | Install in a representative sample line with steady flow. Keep the sensor wetted, avoid trapped air, and provide suitable sample conditioning where water contains particles or bubbles. Check whether pH compensation or a separate pH measurement is needed. | Follow the instrument’s procedure for zero and span checks. Verify readings against a suitable reference method, such as DPD, at intervals set by the application and instrument instructions. | Inspect and clean the sensor and flow cell; check the membrane and electrolyte where applicable. Replace consumable parts according to condition and the maintenance schedule. | Responds continuously but can be affected by changes in flow, temperature, pH, and sensor condition. Confirm that the sensor is suitable for the expected chlorine range and water chemistry. |
| Amperometric, membrane-free | Continuous free-chlorine measurement where the water and installation are compatible with the sensor design. | Provide the sample flow, pressure, temperature, and mounting arrangement specified for the instrument. Ensure the sample is representative and free of conditions that may interfere with the sensing surface. | Check calibration and compare results with a reference method at a frequency based on process risk, operating experience, and instrument guidance. | Clean the sensing surface and flow cell as recommended. Inspect for deposits, coating, or damage that could affect response. | May reduce membrane-related upkeep, but performance remains dependent on water chemistry and correct sample handling. Verify suitability before selection. |
| Reagent-based colorimetric (DPD) | Automated measurement of free or total chlorine in drinking-water treatment, process water, and other applications requiring reagent-based analysis. | Provide a representative sample line, stable sample delivery, drainage, and access for reagent containers. Protect reagents and sample tubing from conditions that could compromise their stability or delivery. | Use the instrument’s calibration or verification procedure and periodically compare results with a recognized reference method. Check reagent condition and expiry when investigating unexpected readings. | Replenish reagents; clean the measurement cell and sample lines; inspect pumps, tubing, and dosing components. Dispose of reagents and waste in accordance with their safety information and local requirements. | Provides a direct chemical measurement but requires reagents and consumables. Sample color, turbidity, or poor reagent delivery may affect results, depending on the system. |
| Oxidation-reduction potential (ORP) sensor | Monitoring oxidation-reduction conditions as a supplementary process indicator. | Install where the sensor contacts a representative, flowing sample. Prevent fouling and ensure the sensor and reference electrode are appropriate for the water and installation. | Check the probe using an appropriate ORP standard solution and follow the sensor instructions. Do not treat an ORP reading as a direct chlorine-concentration calibration. | Clean the electrode; inspect the sensing surface and reference junction; replace or service the probe when its response becomes unreliable. | ORP is influenced by pH, temperature, and other oxidising or reducing substances. It does not directly measure chlorine concentration and should not replace a chlorine analyser when concentration data are required. |
| Portable DPD reference test | Spot checks, commissioning, troubleshooting, and verification of an online analyser. | Collect a fresh, representative sample and test it promptly using the method’s specified procedure. Use clean equipment and observe the method’s sample-handling requirements. | Check the test equipment and reagents as instructed. Use the same chlorine fraction—free or total—when comparing results with an online analyser. | Store reagents correctly, check expiry dates, and clean sample cells after use. | Useful as a field reference, but it is not a continuous measurement. Timing, sampling technique, reagent condition, and operator procedure can affect the result. |
| Selection note: Before purchase, confirm the required chlorine fraction (free or total), measurement range, water chemistry, sample conditions, data outputs, consumable availability, and service access. Set calibration and maintenance intervals using the instrument instructions, site validation results, and the consequences of an incorrect reading. |