| Digital multimeter | AC/DC voltage and current, resistance, continuity; some models measure capacitance, frequency, or temperature. | DC voltage commonly around ±0.5% to ±1.0% of reading, plus counts; check the specification for each range. | Models are available with ratings such as CAT II 600 V or CAT III 600 V. | True-RMS readings can improve AC measurements on non-sinusoidal waveforms. Look for fused current inputs, continuity tone, and clear overload indication. | General electrical troubleshooting where several electrical quantities need to be checked. |
| Clamp meter | AC current without disconnecting the conductor; some models also measure DC current, voltage, resistance, or frequency. | AC current is commonly specified around ±2% to ±3% of reading, plus counts; accuracy depends on range, jaw position, and conductor size. | Models are available with ratings such as CAT III 600 V; confirm the rating applies to the intended measurement and accessories. | True-RMS, inrush-current capture, and a narrow jaw can help with variable loads or crowded panels. Clamp around one conductor for a current reading. | Checking load current and circuit behavior when opening the circuit is undesirable. |
| Insulation resistance tester | Insulation resistance using a selected DC test voltage; some models also provide continuity or voltage checks. | Resistance accuracy is model- and range-dependent; specifications commonly state a percentage of reading plus counts. Check the test-voltage accuracy separately. | Some models carry CAT III 600 V ratings for applicable terminals; the rating does not replace safe isolation procedures. | Selectable test voltages, timed tests, automatic discharge, and a lockable test function can support insulation testing workflows. | Assessing insulation condition in de-energized wiring, motors, and equipment, following the applicable procedure. |
| Two-pole voltage tester | Presence or absence of AC/DC voltage; some models indicate polarity, phase sequence, or continuity. | Usually intended for voltage indication rather than precision measurement; numeric accuracy may not be specified. | Models are available with CAT III or CAT IV ratings at specified voltages. Select a rating appropriate to the measurement location. | A clear voltage indication, proving-unit compatibility, and a design that can be checked before and after use support safe voltage verification. | Verifying voltage presence or absence as part of an approved safe-isolation procedure. |
| Non-contact voltage detector | Indicates an electric field associated with AC voltage near a conductor; it does not provide a measured voltage value. | Not a precision instrument. Detection depends on the device, conductor, distance, shielding, and surrounding conditions. | Check the marked voltage range and applicable safety rating; ratings vary by model. | A visible and audible indication can support preliminary checks, but absence of an indication cannot confirm a circuit is de-energized. | Quick preliminary screening, followed by an appropriate contact voltage test when safety decisions are required. |