| Laser enclosure | Beam containment and access control | Confirm the enclosure is designed for the laser’s wavelength and output, and that access doors prevent laser operation when open. | Review the laser safety documentation and test the door interlock using the manufacturer’s procedure. | Essential |
| Emergency controls | Emergency stop and safe shutdown | Check that the emergency stop is easy to reach and that the machine’s response to activation is clearly documented. | Verify the stop function during commissioning and confirm how the system is reset safely. | Essential |
| Operator protection | Laser eyewear and warning labels | If eyewear is required for the setup, its wavelength range and optical density must match the hazard assessment and applicable rules. Eyewear does not replace a properly enclosed system. | Check eyewear markings, condition, and the machine’s laser classification and warning labels. | Essential |
| Battery-work safeguards | Cell handling, fixturing, and isolation procedures | Look for clear procedures for positioning cells or packs, preventing unintended shorts, and managing damaged or abnormal cells. Battery hazards depend on cell chemistry and state of charge. | Review the work instructions and confirm that fixtures hold parts securely without damaging cells or insulation. | Essential |
| Fire and thermal risk | Risk controls for heat, sparks, and battery incidents | Assess the process for hot workpieces, ignition sources, and possible cell failure. Use site-specific emergency procedures and suitable fire-response arrangements. | Review the risk assessment, emergency plan, and operator training records for the battery chemistry being processed. | Essential |
| Fume management | Local exhaust ventilation and filtration | Determine whether the materials and process generate fumes or particles, and whether extraction is needed. Filtration requirements depend on the materials and system design. | Check airflow or filter-status indicators, service intervals, and the recommended filter type. | High |
| Process control | Parameter control and recipe protection | Evaluate controls for laser power, pulse or weld settings, and repeatable recipes. Check whether access permissions can reduce unintended setting changes. | Run a representative sample weld and confirm that approved settings can be saved, recalled, and documented. | High |
| Cooling system | Cooling alarms and routine checks | For water-cooled equipment, check temperature and flow monitoring, alarm behavior, coolant specifications, and leak inspection requirements. Air-cooled systems have different service needs. | Review the maintenance schedule and confirm that coolant checks and alarm tests are included where applicable. | High |
| Optics and beam path | Protective windows and inspection access | Check how optical surfaces are protected from spatter and contamination, and whether inspection or replacement can be performed using a safe, documented procedure. | Inspect the protective window and ask for cleaning methods, replacement intervals, and approved consumables. | High |
| Electrical safety | Grounding, cables, and service isolation | Check grounding instructions, cable condition, electrical ratings, and isolation procedures for servicing. Follow applicable electrical safety requirements at the installation site. | Inspect cables and connectors, and confirm that maintenance staff have access to the correct isolation instructions. | Essential |
| Maintenance support | Service access, diagnostics, and spare parts | Evaluate whether routine service tasks are clearly documented and whether essential consumables and replacement parts are available within a practical timeframe. | Review the maintenance manual, service intervals, diagnostic messages, and parts list before purchase. | Medium–High |
| Records and training | Operator training and maintenance logs | Confirm that operators can be trained on safe operation, setup, cleaning, fault response, and battery-specific hazards, with maintenance activities recorded. | Check the training materials, logbook or digital record functions, and procedures for reporting faults. | High |