| 1 | Power capacitors | Capacitor units and connection accessories | Low-voltage shunt power capacitors are covered by IEC 60831-1 for AC systems up to and including 1,000 V at 15–60 Hz. | Check rated voltage, capacitance, temperature limits, discharge provisions, and applicable test reports for the offered model. |
| 2 | Detuned reactors | Series reactors for capacitor-bank assemblies | Reactors are selected with the capacitor bank to address harmonic conditions; tuning and thermal design depend on the system study. | Request the reactor rating, impedance or tuning data, loss information, temperature-rise results, and the matching capacitor configuration. |
| 3 | Reactive-power controllers | Measurement, switching logic, and control components | Controller settings depend on the measured network conditions and the required control strategy; a single target power factor is not universal for every installation. | Confirm measurement inputs, switching sequence, alarm functions, settings access, and compatibility with the supplied switching devices. |
| 4 | Capacitor switching devices | Contactors or other capacitor-duty switching components | Capacitor switching can involve inrush current, so devices should be selected for the intended capacitor-duty application. | Verify the device’s declared capacitor-switching duty, voltage and current ratings, endurance data, and coordination with protection. |
| 5 | Protection components | Fuses, circuit-breakers, and related protection accessories | Protection selection depends on rated current, prospective fault current, capacitor-bank configuration, and the assembly design. | Request the protection coordination basis, short-circuit rating, component data sheets, and assembly-level verification documents. |
| 6 | Measurement and sensing | Current transformers, wiring, and measurement interfaces | Correct current-transformer placement and polarity are essential for the controller to measure reactive power in the intended way. | Confirm ratio, accuracy class, burden, installation location, polarity markings, and compatibility with the controller input. |
| 7 | Busbars and internal connections | Conductors, terminals, supports, and connection hardware | Conductor sizing and temperature performance depend on current, installation conditions, enclosure design, and the applicable assembly requirements. | Check material, dimensions, rated current, clearances, connection torque instructions, and supporting test or design evidence. |
| 8 | Enclosures and thermal management | Cabinets, mounting structures, ventilation, and related parts | Heat dissipation and environmental protection need to be assessed for the complete assembled bank and its installation environment. | Specify enclosure protection, ambient conditions, ventilation arrangement, access requirements, and temperature-rise evidence. |
| 9 | CKD assembly and integration | Component kits, assembly instructions, and integration support | IEC 61439-1 sets general rules for low-voltage switchgear and controlgear assemblies; component conformity alone does not establish conformity of the finished assembly. | Agree on the bill of materials, drawings, wiring diagrams, assembly responsibility, inspection plan, and applicable assembly verification. |
| 10 | Testing and documentation | Routine checks, records, and technical files | China’s public electricity supply uses a 50 Hz frequency; nominal voltage and installation conditions must be confirmed for the specific project. | Request traceable model-specific reports, routine inspection records, nameplate data, installation instructions, and warranty terms. |