| 1. Light-gauge steel frame | Cold-formed steel wall and roof framing, assembled on site or from prefabricated panels. | Energy-code compliance report for the applicable climate zone; insulation, air-leakage, and thermal-bridge details. | Code-compliant framing design, connection details, and required material documentation under the locally adopted code. | Site-specific wind, snow, seismic, and other applicable loads; load paths and anchorage. | Not inherently rated; depends on the complete design and jurisdiction. |
| 2. Structural insulated panel (SIP) with steel frame | Insulated wall or roof panels combined with a steel structural frame or steel connections. | Assembly R-values or U-factors, panel-joint air-sealing details, and a code-accepted compliance method. | Panel evaluation or engineering documents, connection design, and fire and moisture details as required. | Wind and snow pressures on panels, diaphragm design, connections, and foundation anchorage. | No universal rating; verify the exact panel assembly and project documents. |
| 3. Volumetric modular steel-frame house | Factory-built three-dimensional modules joined and finished at the site. | Energy calculations for the completed building, including module joints, windows, doors, and mechanical systems. | Factory and site inspection records where required; module connection, egress, fire, and structural documents. | Building and module loads, lifting and transport design where applicable, inter-module connections, and site loads. | Approval is project- and jurisdiction-specific; factory construction alone is not a rating. |
| 4. Panelized steel-frame house | Factory-made wall, floor, or roof panels assembled at the building site. | Whole-building compliance documentation and insulation continuity details at panel edges and openings. | Panel shop drawings, field connection schedule, bracing design, and required inspection documentation. | Wind and seismic force transfer through panel joints, roof-to-wall connections, and anchorage. | Not rated by construction format; confirm the engineered design and approved plans. |
| 5. Steel frame with insulated metal panels | Steel framing with factory-insulated metal wall and/or roof panels. | Tested or documented thermal performance for the specified panel, joints, penetrations, and complete envelope. | Panel approvals and installation details; fire, structural, and water-management requirements for the project. | Panel attachment and frame design for applicable wind, snow, and seismic demands. | Panel performance is product-specific; the whole building still requires code review. |
| 6. Steel moment-frame prefab house | Prefabricated steel frame with moment-resisting connections and separately designed walls and envelope. | Envelope and mechanical-system compliance documents; the frame type does not establish energy performance. | Engineer-stamped frame and connection design, plus applicable inspection and material records. | Seismic design parameters where applicable, wind loads, drift limits, and foundation connections. | No general safety score; verify the design for the actual site and code edition. |
| 7. Steel braced-frame prefab house | Steel frame with diagonal bracing; wall and roof assemblies may be factory-panelized. | IECC compliance documentation for the insulated envelope, air sealing, windows, and HVAC equipment. | Bracing layout and connection calculations, coordinated with openings and architectural plans. | Applicable wind and seismic forces, brace and connection forces, torsion, and load path to foundation. | Performance cannot be inferred from the system name; request signed calculations. |
| 8. Steel-frame house with a cool roof | Steel structure with a roof assembly selected for solar reflectance and thermal emittance where appropriate. | Roof product data plus whole-building energy compliance; a reflective roof alone does not establish compliance. | Roof assembly, fire classification where required, attachment details, and structural roof design. | Wind uplift, snow loads where applicable, roof framing, and attachment to the main structure. | Energy benefit varies by climate and assembly; no universal house rating. |
| 9. Steel-frame house with high-performance glazing | Steel structure paired with windows selected for climate-appropriate U-factor and solar heat gain coefficient. | Window NFRC ratings where available, whole-building calculations, and installation and air-sealing details. | Safety glazing, opening and egress requirements, product documentation, and structural attachment details. | Window and wall pressures, glass design where required, and frame and connection loads. | Window labels apply to specified products, not to the house as a whole. |
| 10. Steel-frame house with a continuous-insulation envelope | Steel framing combined with continuous insulation and carefully detailed air and water-control layers. | Assembly U-factor or documented R-value, thermal-bridge treatment, air-leakage strategy, and code-compliance report. | Wall assembly and attachment details, fire and moisture provisions, and structural design for cladding loads. | Cladding and insulation attachment under wind loads; frame, roof, and foundation design for site-specific loads. | Potential energy performance depends on tested or calculated assemblies and correct installation. |