| Gifford–McMahon (GM) | A compressor circulates helium through a regenerator and a displacer-driven cold head. Expansion and regenerative heat exchange produce refrigeration. | Commonly used from roughly 4 K to 80 K, depending on the system and cooling stage. | Cryopumps, superconducting equipment, and laboratory cryostats. | Can reach very low temperatures and is available in single- and multistage configurations. | The cold head has moving parts and may transmit vibration; compressor and maintenance needs should be considered. | Very low temperatures or established cryogenic-system integration are priorities. |
| Pulse tube | Oscillating helium gas moves heat through a regenerator and pulse tube. The cold end has no moving displacer. | Systems are designed for different ranges, commonly from about 4 K to 100 K. | Low-vibration research equipment, superconducting devices, and cryogenic instruments. | No moving parts at the cold head can reduce vibration and cold-head wear. | The compressor still has moving parts; cooling capacity and vibration depend on system design and operating conditions. | Low cold-head vibration matters, especially for sensitive experiments or instruments. |
| Stirling | A sealed working gas is cyclically compressed and expanded, with a regenerator transferring heat between parts of the cycle. | Often used in the tens-of-kelvin range; the achievable temperature depends on the design and heat load. | Infrared sensors, thermal imaging systems, and compact cryogenic instruments. | Can be compact and suitable for integration into equipment. | Moving components can create vibration and require attention to service life and operating conditions. | A compact cooler is needed for a sensor or instrument operating above the lowest helium-temperature range. |
| Joule–Thomson (JT) | A pressurized gas expands through a restriction, causing cooling under suitable conditions. Many systems use precooling and a recuperative heat exchanger. | Application-dependent; specialized systems can reach cryogenic temperatures, while the gas and precooling arrangement determine performance. | Gas liquefaction, cryogenic probes, and specialized cooling applications. | Can provide cooling at a remote cold tip and can be configured for particular working gases and applications. | Requires suitable high-pressure gas handling; performance depends strongly on gas choice, inlet conditions, and precooling. | A remote cold tip or a gas-specific refrigeration process is required. |
| Liquid-nitrogen cooling system | Liquid nitrogen absorbs heat as it boils, cooling a vessel, sample, or circulating thermal loop. It is a cryogen supply, not a mechanical cryocooler. | Approximately 77 K at atmospheric pressure; actual equipment temperatures depend on heat transfer and operating pressure. | Sample cooling, laboratory equipment, and processes compatible with nitrogen-temperature cooling. | Provides a straightforward route to temperatures near liquid nitrogen’s boiling point. | Needs cryogen replenishment, suitable ventilation, and precautions against cold burns and oxygen displacement. | Cooling near 77 K is sufficient and liquid-nitrogen handling is acceptable. |