| Compact distribution valve | DN100 (4 in) | Small-diameter water distribution branches and isolation points | Flanged; confirm flange drilling and facing | Manual gear operator | Rubber-seated design; select body, disc, shaft, and elastomer materials for the water chemistry | Confirm installation space, operating torque, pressure class, and potable-water approvals if required |
| Branch-line isolation valve | DN150 (6 in) | Distribution mains, treatment-plant branches, and utility isolation | Flanged; verify the mating flange standard | Manual gear operator with position indication | Specify elastomer compatibility and suitable internal/external coating for the service environment | Check face-to-face dimensions, shutoff requirements, and operating direction |
| Small transmission-main valve | DN200 (8 in) | Water transmission and process piping with routine isolation needs | Flanged or another documented C504-compatible end arrangement | Manual gear operator | Choose shaft and disc details with corrosion resistance and maintenance access in mind | Review flow velocity, differential pressure, and allowable head loss |
| Utility network valve | DN250 (10 in) | Municipal distribution networks and pump-station piping | Flanged; confirm drilling, dimensions, and gasket requirements | Manual gear operator; prepare for actuator mounting if needed | Use a resilient seat suited to the fluid and expected operating temperature | Confirm pressure class, buried-service coating, and access to the gearbox |
| General-purpose main valve | DN300 (12 in) | Water mains, reservoirs, and treatment-plant isolation | Flanged or specified mechanical-joint arrangement, subject to the valve design | Manual gear operator | Ductile-iron components and corrosion-resistant shaft materials are common choices; verify the offered specification | Check installation orientation, shutoff pressure, and any potable-water certification requirements |
| Medium transmission valve | DN350 (14 in) | Transmission pipelines and large facility headers | Flanged; match the pipeline flange standard | Gear operator; electric actuation may be specified for remote control | Provide actuator mounting and electrical interface details when automation is required | Confirm torque data, cycle frequency, power supply, and fail-position requirements |
| Large distribution-main valve | DN400 (16 in) | Major distribution mains and pumping-system isolation | Flanged; verify face-to-face and flange dimensions | Manual gear operator or a suitably sized actuator | Check coating system, seat replaceability, and access for inspection | Review surge conditions, differential pressure, and the valve’s permitted installation position |
| Plant-header valve | DN500 (20 in) | Large treatment-plant headers and regional water-system pipelines | Flanged or another project-specified end connection | Gear operator; powered actuation for frequent or remote operation | Confirm that the proposed disc, shaft, and elastomer materials suit the fluid and environment | Request certified dimensional drawings, operating torque, and pressure-test documentation |
| Large transmission valve | DN600 (24 in) | Transmission mains, reservoirs, and large pumping stations | Flanged; verify mating-pipeline standards and drilling | Actuator-ready gear operator or specified powered actuator | Plan lifting points, structural support, actuator clearance, and maintenance access | Check surge analysis, control requirements, and transport dimensions |
| Extra-large pipeline valve | DN750 (30 in) | Large-capacity transmission systems and major plant piping | Project-specific; confirm the offered end arrangement and interface dimensions | Powered actuator or engineered gear operator, selected from verified torque data | Coordinate valve, actuator, controls, supports, and site installation sequence | Verify size/class availability, delivery limits, lifting plan, and full submittal package |