| Road-lighting performance | Photometric design for the actual road, street layout, pole height, spacing, and mounting angle. | Compare maintained illuminance and uniformity against the applicable local road-lighting standard and project requirements. Do not select a luminaire from wattage alone. | Project-specific lighting calculation and luminaire IES or EULUMDAT file. |
| Energy efficiency | Luminaire efficacy in lumens per watt, measured at the complete fixture level. | Compare tested system efficacy at the proposed power and operating conditions. Check that the figure includes the driver and is supported by a recognized test method. | Photometric test report, rated input power, and product datasheet. |
| Light quality and color | Correlated color temperature (CCT), color rendering, glare, and optical distribution. | Choose CCT and optics to suit the road, surrounding environment, local policy, and ecological requirements. There is no single CCT that is best for every location. | Available CCT and color-rendering data, plus photometric files and glare-related design information. |
| Weather and impact protection | Ingress protection (IP) and impact protection (IK) ratings for the complete luminaire. | IP66 is a common outdoor-luminaire target for protection against dust and powerful water jets. Consider higher impact protection, such as IK10, where vandalism or impact risk warrants it. | Test reports for the offered configuration; confirm ratings apply to the assembled luminaire and installed accessories. |
| Surge and electrical protection | Surge protection, grounding, driver protection, and compatibility with the local supply network. | Specify surge protection based on local lightning exposure, grid conditions, and project requirements. Confirm the protection level and test basis rather than relying on a generic “surge protected” claim. | Driver and surge-protection specifications, wiring diagram, and applicable electrical test documentation. |
| Controls and dimming | Supported dimming methods, control interfaces, schedules, and fallback behavior. | Confirm compatibility with the chosen control system and whether dimming follows an open standard such as DALI-2 or a specified ANSI/NEMA or Zhaga interface. Check behavior if communications fail. | Interface specifications, interoperability documentation, and a demonstration of dimming and fail-safe operation. |
| Connectivity and coverage | Communication technology, network topology, coverage, and dependence on external infrastructure. | Assess cellular, radio mesh, or other proposed connectivity against site coverage, data costs, gateway needs, and local spectrum rules. Verify performance with a site survey or pilot. | Network architecture, coverage assumptions, gateway requirements, and recurring connectivity costs. |
| Interoperability and data access | Integration with management platforms, third-party systems, and exportable operational data. | Clarify which interfaces and APIs are available, who owns the data, and whether another service provider can operate the system without proprietary restrictions. | Interface documentation, data-export formats, integration references, and written access and ownership terms. |
| Cybersecurity and updates | Device identity, access control, encryption, vulnerability handling, and software-update process. | Ask how devices are authenticated, how credentials are managed, how vulnerabilities are reported, and how security updates are delivered over the expected service life. | Security policy, update-support period, incident-contact process, and relevant product security documentation. |
| Operating environment | Rated ambient temperature, humidity, corrosion resistance, and suitability for coastal, dusty, or high-altitude sites. | Check that the stated operating range covers the project’s actual conditions, including enclosure temperature and the expected local extremes. | Environmental ratings, materials and coating details, and test reports for the specified configuration. |
| Serviceability and lifetime | Replaceable components, access to drivers and control nodes, and documented lifetime assumptions. | Compare component-level repair options and maintenance procedures. Treat LED lifetime figures as conditional on stated temperature, current, and maintenance assumptions. | Maintenance manual, spare-parts list, lifetime report, and warranty terms with exclusions clearly stated. |
| Compliance and certification | Safety, electromagnetic compatibility, radio, and market-specific regulatory requirements. | Identify requirements for every destination market; a certificate or approval for one region does not automatically establish compliance elsewhere. | Declarations of conformity and relevant test reports for the exact product and radio configuration being supplied. |
| Total cost of ownership | Purchase price, installation, energy, communications, software, maintenance, and replacement costs. | Compare costs over the same analysis period and operating schedule. Include platform fees, gateways, data plans, training, and any vendor-specific service charges. | Itemized quotation, energy-savings assumptions, service pricing, and lifecycle-cost model. |
| Pilot and deployment support | Commissioning process, documentation, training, local support, and ability to scale. | Run a representative pilot before a large rollout. Verify installation, network coverage, control behavior, energy reporting, and maintenance workflows on site. | Pilot plan, commissioning checklist, training materials, support response terms, and deployment references. |