| What it is | A luminaire designed and certified for use in specified hazardous locations where flammable gas, vapor, mist, or combustible dust may be present. | Its protection depends on the complete certified construction and installation—not on the LED light source alone. Follow the product certificate and installation instructions. |
| Hazardous-area classification | The site’s applicable system and area classification, such as IEC/ATEX Zones or North American Class/Division or Zone designations. | Confirm the exact location classification with the site’s hazardous-area documentation and the authority having jurisdiction. Do not assume that Zone and Division markings are interchangeable. |
| Gas or dust group | The required gas/vapor or combustible-dust group stated in the equipment marking and certification. | Verify that the marked group covers the substances present at the site. Gas and dust classifications use different group systems. |
| Temperature class and surface temperature | The luminaire’s marked temperature class or maximum surface temperature, compared with the ignition requirements of the site’s substances. | Select equipment whose permitted temperature is suitable for the identified hazard, including the expected ambient temperature and operating conditions. |
| Certification and marking | Applicable approvals and the full equipment marking, such as ATEX or IECEx certification where required, or approvals applicable in the installation jurisdiction. | Check the certificate, permitted area, gas or dust group, temperature limits, ambient range, and any special conditions of use. A general-purpose IP rating is not hazardous-area certification. |
| Ingress protection and environment | The IP rating, corrosion resistance, resistance to water or dust exposure, and suitability for the site’s cleaning and weather conditions. | Choose an enclosure suitable for the actual environment. IP protection addresses ingress under defined test conditions; it does not establish explosion protection. |
| Light output and efficacy | Delivered lumens, lumens per watt, mounting height, task illuminance, and the effects of optics and enclosure design. | Base the selection on a lighting layout or photometric calculation for the task area. Do not compare fixtures by wattage alone. |
| Beam distribution and glare | Available beam patterns, aiming requirements, uniformity, spill light, and glare at the intended mounting position. | Select optics for the application—for example, broad coverage for open areas or a more controlled distribution for specific work zones—and verify the result with photometric data. |
| Ambient temperature | The certified operating ambient range, including local heat sources, weather, and enclosure conditions. | Ensure the expected site temperature falls within the luminaire’s marked and certified range; output or service life may be affected outside specified conditions. |
| Electrical supply and controls | Supply voltage and frequency, driver compatibility, inrush current, dimming method, and any required emergency-lighting arrangement. | Confirm electrical ratings and permitted accessories against the equipment documentation. Use only controls and components suitable for the hazardous-area installation. |
| Construction and mounting | Housing and lens materials, mounting orientation, bracket strength, cable entries, and compatibility with the site’s corrosion and vibration conditions. | Check that cable glands, conduit entries, fasteners, and mounting accessories match the certified configuration and local installation requirements. |
| Maintenance and lifecycle | Cleaning access, replaceable parts, driver and LED service information, warranty terms, and required inspection procedures. | Plan inspection and maintenance in accordance with the manufacturer’s instructions and applicable regulations. Isolate power and follow site safety procedures before servicing. |